Resultado da pesquisa (2)

Termo utilizado na pesquisa Nogueira G.P

#1 - B-mode ultrasonography and gray scale histogram for evaluation of the nuchal ligament in Quarter horse

Abstract in English:

The gray scale histogram (GSH) makes it possible to measure the amount and distribution of gray shade frequencies, providing quantitative information on both echogenicity and echotexture of tissues. There is a need to diminish the subjectivity of the ultrasound images of the nuchal ligament (NL). This work proposes to evaluate the NL by ultrasound B-mode GSH images in different ages of Quarter horses. It used 15 healthy Quarter horses, which were classified by age into three different groups: “baby” (1), “sobreano” (2) and “adult” (3). The animals were submitted to chemical restraint for the ultrasound examination. Subsequently, the GSH tool was used in each image for statistical analysis. There was a significant difference between Mean and Mode between groups. Group 1 differed significantly when compared to Group 2 and 3. Group 2 presented superior echogenicity to Group 1 and 3. The height of the NL did not vary considerably between groups. GSH indicated that the echogenicity of NL in Quarter horses varies with age.

Abstract in Portuguese:

O histograma em escala de cinza (HEC) possibilita a mensuração da quantidade e distribuição da frequência de tonalidades de cinza, fornecendo informações quantitativas, tanto sobre a ecogenicidade quanto a ecotextura dos tecidos. Havendo a necessidade de diminuir a subjetividade das imagens ultrassonográficas do ligamento nucal (LN), esse trabalho propôs avaliar o LN por imagens ultrassonograficas modo-B pelo HEC em diferentes idades de cavalos da raça Quarto de Milha. Utilizou 15 cavalos da raça Quarto de Milha saudáveis os quais foram classificados por idade em três grupos diferentes: “baby” (1), “sobreano” (2) e “adulto” (3). Os animais foram submetidos a contenção química para a realização do exame ultrassonográfico. Posteriormente, a ferramenta HEC foi empregada em cada imagem para análise estatística. Houve diferença significativa entre as variáveis “Mean” e “Mode” entre os grupos. O Grupo 1 diferenciou significativamente quando comparado ao Grupo 2 e 3. O Grupo 2 apresentou ecogenicidade superior ao Grupo 1 e 3. Quanto à altura do LN não teve variação considerável entre os grupos. O HEC indicou que a ecogenicidade do LN em cavalos Quarto de Milha varia conforme a idade.


#2 - Standardization of ELISA for the measurement of Insulin-Like Growth Factor I (IGF-I) in bovine plasm, 37(12):1545-1553

Abstract in English:

ABSTRACT.- Maioli M.A. & Nogueira G.P. 2017. [Standardization of ELISA for the measurement of Insulin-Like Growth Factor I (IGF-I) in bovine plasm.] Padronização da quantificação do fator de crescimento semelhante a insulina I (IGF-I) em plasma bovino por ELISA. Pesquisa Veterinária Brasileira 37(12):1545-1553. Departamento de Apoio a Produção e Saúde Animal, Faculdade de Medicina Veterinária de Araçatuba, Universidade Estadual Paulista, Unesp-Araçatuba, Rua Clóvis Pestana 793, Araçatuba, SP 16050-680, Brazil. E-mail: maioli_marcos@hotmail.com This study aimed to standardize an in house competitive enzyme-linked immunosorbent assay (cELISA) to determine plasma concentrations of total insulin-like growth factor I (IGF-I) for the bovine specie using the amplification biotin-streptavidin peroxidase system. The IGF-I was extracted from insulin-like growth factor binding proteins (IGFBPs) using the acidified glycine buffer followed by the pH neutralization with sodium hydroxide. The microplates were coated with anti-rabbit IgG, thereafter the measurements were carried out using two approaches, one with a prior incubation of samples with the anti-h-IGF-I antibody and another without previous incubation (simultaneous addition of IGF-I and biotinylated sample). The best results were obtained using the method without the prior incubation, using the following combination of reagents: microplates were coated with 0.25µg/well of anti-rabbit IgG, the specific antibody at a dilution of 1:250,000 and 0.06ng/well of biotinylated IGF-I. The in house methodology showed sensitivity of 50ng/ml, a correlation between doses of 0.945 when compared to a commercial method. In addition, after 33 assays (quantification of 1114 samples) the proposed methodology presented a good precision, with inter-assay variation coefficients of 12.94% and 20.71% for the high and low controls, respectively. Finally, we concluded that ELISA method for the quantification of total IGF-I using the system biotin-streptavidin-peroxidase amplification in a competitive assay is established and is presented as a useful tool for studies aimed at monitoring the IGF-I concentrations.

Abstract in Portuguese:

RESUMO.- Maioli M.A. & Nogueira G.P. 2017. [Standardization of ELISA for the measurement of Insulin-Like Growth Factor I (IGF-I) in bovine plasm.] Padronização da quantificação do fator de crescimento semelhante a insulina I (IGF-I) em plasma bovino por ELISA. Pesquisa Veterinária Brasileira 37(12):1545-1553. Departamento de Apoio a Produção e Saúde Animal, Faculdade de Medicina Veterinária de Araçatuba, Universidade Estadual Paulista, Unesp-Araçatuba, Rua Clóvis Pestana 793, Araçatuba, SP 16050-680, Brazil. E-mail: maioli_marcos@hotmail.com Esse estudo teve como objetivo a padronização de um ensaio imunoenzimático competitivo (cELISA) in house para a determinação das concentrações plasmáticas do fator de crescimento semelhante a insulina I (IGF-I) total para a espécie bovina, utilizando o sistema de amplificação biotina-estreptavidina peroxidase. O IGF-I foi extraído das proteínas ligadoras do fator de crescimento semelhante a insulina I (IGFBP), utilizando o tampão glicina acidificado seguido de neutralização do pH com hidróxido de sódio. As microplacas foram sensibilizadas com anti IgG de coelho, e as dosagens realizadas utilizando duas abordagens, um método com incubação prévia das amostras com o anticorpo anti-h-IGF-I e outro sem incubação prévia (adição simultânea de IGF-I biotilinado e amostra). Os melhores resultados foram obtidos utilizando o método sem incubação prévia, com a sensibilização da placa com 0,25μg/poço de anti-IgG de coelho, o anticorpo específico na diluição 1:250.000 e 0,06ng/poço de IGF-I biotinilado. O ensaio in house apresentou um limite inferior de detecção de 50ng/mL, uma correlação de 0,945 entre doses quando comparado a uma metodologia comercial. Os coeficientes de variação inter-ensaio de 12,94% (345,8ng/mL) para os controles alto e 20,71% (131,6ng/mL) para o baixo. Dessa forma, conclui-se que a metodologia imunoenzimática para quantificação de IGF-I total utilizando o sistema de amplificação biotina-estreptavidina peroxidase em um ensaio competitivo está estabelecida e apresenta-se como uma ferramenta útil para estudos que visem o monitoramento das concentrações de IGF-I.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV